(1)Power Source: The CO₂ cylinder serves as the power source for the beauty syringe. By releasing the high-pressure carbon dioxide gas inside the cylinder, it generates pressure to push the piston of the syringe, enabling the syringe to precisely inject beauty filling materials, such as hyaluronic acid and collagen, into specific layers of the skin. This power mode allows for precise dosage control, ensuring that the filling materials are evenly and accurately distributed in the target area, thus achieving the desired cosmetic effect.
(2)Safety Assurance: Compared with some other power driving methods, the pressure provided by the CO₂ cylinder is relatively stable and easy to control. During the beauty injection process, the stable pressure helps to avoid inaccurate injection volume caused by sudden pressure changes or unnecessary damage to the skin tissue, providing a certain level of safety assurance for the beauty injection operation. At the same time, CO₂ is a relatively safe and inert gas that is not likely to chemically react with the beauty filling materials, and it will not affect the properties and effects of the filling materials.
(1)Select Regular Products: Choose CO₂ cylinders with medical device qualifications and that have passed strict quality inspections to ensure that they meet relevant safety standards. For example, the cylinder should have qualified pressure resistance performance and be able to withstand the pressure during normal use without bursting or leaking.
(2)Check the Appearance and Markings: Carefully check the appearance of the cylinder to ensure that there are no obvious damages, corrosion, deformations, or other defects. At the same time, confirm that the markings on the cylinder are clear and complete, including information such as the gas type, pressure, production date, and service life, so as to accurately understand the basic situation and usage requirements of the cylinder.
(1)Professional Installation: Have the CO₂ cylinder installed by trained medical staff in accordance with the operation procedures to ensure that the connection between the cylinder and the beauty syringe is tight and firm, preventing gas leakage.
(2)Reliable Fixation: Properly fix the cylinder in the corresponding position of the syringe to avoid shaking, collision, or accidental detachment during use, and reduce the risk of damage to the cylinder caused by mechanical collisions.
(1)Install a Pressure Monitoring Device: Set up a pressure monitoring instrument in the beauty syringe system to monitor the pressure changes inside the CO₂ cylinder in real time. When the pressure exceeds the normal range, it can promptly issue an alarm to remind the operator to stop using it and conduct an inspection.
(2)Reasonably Control the Pressure: According to the specific needs of beauty injection and the characteristics of the skin in different parts, precisely adjust and control the pressure output of the CO₂ cylinder to avoid damage to the skin tissue caused by excessive pressure or poor injection effects caused by insufficient pressure.
(1)Daily Inspection: Before each use, the operator should conduct an appearance inspection of the CO₂ cylinder to check for signs of leakage, such as hissing sounds of gas or frost on the surface of the cylinder. At the same time, check the tightness of the connection parts to ensure that there is no looseness or air leakage.
(2)Regular Maintenance: In accordance with the suggestions of the cylinder manufacturer and relevant regulations, regularly send the CO₂ cylinder to a professional institution for comprehensive maintenance and inspection. This includes pressure resistance testing of the cylinder, checking the tightness of the valve, internal cleaning, etc., to promptly detect and address potential safety hazards.
If you are interested in the specific details of the various weights of our CO₂ cylinders, you can click the link below to learn more.
33g CO₂ cylinder with threads of 3/8-24UNF |